Omnidirectional globe
Use a 360° isotropic source to convert lumens to average candela. A cone footprint does not apply.
Inputs
View results ↑- Intensity
- 119.4cd
- Beam center
- 3.42fc
- Beam diameter
- —
- Luminance
- 2.33fL
Solid-angle cone and receiving plane
Edit inputs ↓Beam center target
Within screenOutsideThresholdWithin
- Axial illuminance3.42 / ≥ 3.25 fc within screen
The target applies on the optical axis.
Additional readings
| Luminous flux | 1,500lm |
|---|---|
| Solid angle | 12.5664sr |
| Luminaire efficacy | 107.14lm/W |
| Diameter at the receiving plane | — |
Worked calculation
US customary results for the original preset.
- Convert the full beam angle of 360 ° to 12.5664 sr. The uniform-cone relationship pairs 1500 lm with 119.37 cd.
- At a throw of 5.91 ft, the center receives 3.42 fc. A full sphere has no cone diameter.
- Apply diffuse reflectance 0.68 to estimate 2.33 fL at the center.
Calculation method
In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.
- Beam solid angle and flux
- Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
- Beam footprint and center
- Diameter = 2d tan(α/2) · Ecenter = I/d²
- Diffuse luminance and efficacy
- L = Ecenter × ρ/π · efficacy = Φ/W
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.
Sources and assumptions ↗LightingLuxLab · US customary
Omnidirectional globe
Inputs
| Calculate from | Luminous flux · lumens |
|---|---|
| Luminous flux | 1,500lm |
| Full beam angle | 360° |
| Electrical input | 14W |
| Axial throw | 5.9055118ft |
| Diffuse reflectance | 0.68 |
| Center illuminance target | 3.2516064fc |
Results
| Intensity | 119.4cd |
|---|---|
| Beam center | 3.42fc |
| Beam diameter | — |
| Luminance | 2.33fL |
| Luminous flux | 1,500lm |
| Solid angle | 12.5664sr |
| Luminaire efficacy | 107.14lm/W |
| Diameter at the receiving plane | — |
Beam center target
- Axial illuminance · 3.42 / ≥ 3.25 fc · Within screen
The target applies on the optical axis.
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.