Lumens, Candela & Beam Angle
Convert flux and candela in a uniform cone, then estimate beam spread, center illuminance, and diffuse surface luminance.
Inputs
View results ↑- Intensity
- 5,258.3cd
- Beam center
- 36.52fc
- Beam diameter
- 8.26ft
- Luminance
- 23.74fL
Solid-angle cone and receiving plane
Edit inputs ↓Beam center target
Within screenOutsideThresholdWithin
- Axial illuminance36.52 / ≥ 30 fc within screen
The target applies on the optical axis.
Additional readings
| Luminous flux | 1,800lm |
|---|---|
| Solid angle | 0.3423sr |
| Luminaire efficacy | 105.88lm/W |
| Diameter at the receiving plane | 8.26ft |
Calculation method
In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.
- Beam solid angle and flux
- Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
- Beam footprint and center
- Diameter = 2d tan(α/2) · Ecenter = I/d²
- Diffuse luminance and efficacy
- L = Ecenter × ρ/π · efficacy = Φ/W
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.
Sources and assumptions ↗LightingLuxLab · US customary
Lumens, Candela & Beam Angle
Inputs
| Calculate from | Luminous flux · lumens |
|---|---|
| Luminous flux | 1,800lm |
| Full beam angle | 38° |
| Electrical input | 17W |
| Axial throw | 12ft |
| Diffuse reflectance | 0.65 |
| Center illuminance target | 30fc |
Results
| Intensity | 5,258.3cd |
|---|---|
| Beam center | 36.52fc |
| Beam diameter | 8.26ft |
| Luminance | 23.74fL |
| Luminous flux | 1,800lm |
| Solid angle | 0.3423sr |
| Luminaire efficacy | 105.88lm/W |
| Diameter at the receiving plane | 8.26ft |
Beam center target
- Axial illuminance · 36.52 / ≥ 30 fc · Within screen
The target applies on the optical axis.
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.