Ground-end detent spring
A small detent uses a plain-and-ground stainless spring with moderate working deflection.
Anatomy
Axial compression between supports
Screening margins
Exceeds screen-
Working shear323.8 MPa / 540 MPa
Within screen -
Shear at solid761 MPa / 540 MPa
Exceeds screen -
BucklingAbsolutely stable in this model
— -
Travel to solid5 mm / 11.75 mm
Within screen
Calculated values
| Axial spring rate k | 7.0096 N/mm |
|---|---|
| Working force F | 35.048 N |
| Working shear stress τ | 323.84 MPa |
| First axial surge frequency | 779.12 Hz |
| Spring index C | 6.6667 |
| Wahl factor K_w | 1.2246 |
| Total coils Nₜ | 7.5 |
| Solid height Lₛ | 11.25 mm |
| Working length L₀ − y | 18 mm |
| Travel to solid | 11.75 mm |
| Working clearance to solid | 6.75 mm |
| Force at solid height | 82.363 N |
| Estimated stress at solid | 761.02 MPa |
| Free slenderness L₀/D | 2.3 |
| Absolute stability L₀/D limit | 5.1973 |
| Critical buckling travel | — |
Starting result
Look at the difference between active and total coils. Only active turns contribute to the rate and surge mass.
- Total coils Nₜ
- 7.5
- Axial spring rate k
- 7.0096 N/mm
- First axial surge frequency
- 779.12 Hz
Model and assumptions
k = Gd⁴/(8D³Nₐ) · τ = K_w·8FD/(πd³) · f₁ = ½√(k/mₐ) for seated ends
Round wire and a linear rate up to solid. Buckling uses Wahl–Haringx lateral stability with the selected end restraint. Fixed–fixed assumes restrained seats. Surge uses active wire mass, with the fixed–free frequency halved.
References and calculation method