Surge from specific weight
A machine designer has wire specific weight in N/m³ from a material data sheet.
Anatomy
Axial compression between supports
Screening margins
Within screen-
Working shear209 MPa / 650 MPa
Within screen -
Shear at solid548.7 MPa / 650 MPa
Within screen -
BucklingAbsolutely stable in this model
— -
Travel to solid12 mm / 31.5 mm
Within screen
Calculated values
| Axial spring rate k | 9.4036 N/mm |
|---|---|
| Working force F | 112.84 N |
| Working shear stress τ | 209.01 MPa |
| First axial surge frequency | 205.38 Hz |
| Spring index C | 7.4286 |
| Wahl factor K_w | 1.1995 |
| Total coils Nₜ | 11 |
| Solid height Lₛ | 38.5 mm |
| Working length L₀ − y | 58 mm |
| Travel to solid | 31.5 mm |
| Working clearance to solid | 19.5 mm |
| Force at solid height | 296.21 N |
| Estimated stress at solid | 548.65 MPa |
| Free slenderness L₀/D | 2.6923 |
| Absolute stability L₀/D limit | 5.1973 |
| Critical buckling travel | — |
Starting result
The surge calculation uses mass. Specific weight is converted with standard gravity before calculating frequency.
- Axial spring rate k
- 9.4036 N/mm
- First axial surge frequency
- 205.38 Hz
- Solid height Lₛ
- 38.5 mm
Model and assumptions
k = Gd⁴/(8D³Nₐ) · τ = K_w·8FD/(πd³) · f₁ = ½√(k/mₐ) for seated ends
Round wire and a linear rate up to solid. Buckling uses Wahl–Haringx lateral stability with the selected end restraint. Fixed–fixed assumes restrained seats. Surge uses active wire mass, with the fixed–free frequency halved.
References and calculation method