Long spring buckling check
A long squared-end spring works between pivoting supports in an open fixture.
Anatomy
Axial compression between supports
Screening margins
Exceeds screen-
Working shear311.3 MPa / 650 MPa
Within screen -
Shear at solid1,261 MPa / 650 MPa
Exceeds screen -
Buckling travel20 mm / 14.34 mm
Exceeds screen -
Travel to solid20 mm / 81 mm
Within screen
Calculated values
| Axial spring rate k | 5.8081 N/mm |
|---|---|
| Working force F | 116.16 N |
| Working shear stress τ | 311.32 MPa |
| First axial surge frequency | 186.3 Hz |
| Spring index C | 8 |
| Wahl factor K_w | 1.184 |
| Total coils Nₜ | 12 |
| Solid height Lₛ | 39 mm |
| Working length L₀ − y | 100 mm |
| Travel to solid | 81 mm |
| Working clearance to solid | 61 mm |
| Force at solid height | 470.46 N |
| Estimated stress at solid | 1,260.9 MPa |
| Free slenderness L₀/D | 5 |
| Absolute stability L₀/D limit | 2.5986 |
| Critical buckling travel | 14.343 mm |
Starting result
Compare working travel with the buckling onset. The spring can lose lateral stability with clearance still remaining to solid.
- Free slenderness L₀/D
- 5
- Critical buckling travel
- 14.343 mm
- Travel to solid
- 81 mm
Model and assumptions
k = Gd⁴/(8D³Nₐ) · τ = K_w·8FD/(πd³) · f₁ = ½√(k/mₐ) for seated ends
Round wire and a linear rate up to solid. Buckling uses Wahl–Haringx lateral stability with the selected end restraint. Fixed–fixed assumes restrained seats. Surge uses active wire mass, with the fixed–free frequency halved.
References and calculation method