Surge from specific weight

A machine designer has wire specific weight in N/m³ from a material data sheet.

Input units
Spring rate 9.4036 N/mm
Working load 112.84 N
Wahl shear 209.01 MPa
Surge mode 205.38 Hz

Anatomy

Axial compression between supports

Edit inputs
Axial compression between supportsSchematic view with the current loads and dimensions. FREEWORKINGSOLIDFree L₀70 mmWorking L58 mmSolid Lₛ38.5 mm

Screening margins

Within screen
  • Working shear209 MPa / 650 MPa
    Within screen
  • Shear at solid548.7 MPa / 650 MPa
    Within screen
  • BucklingAbsolutely stable in this model
    —
  • Travel to solid12 mm / 31.5 mm
    Within screen

Calculated values

Axial spring rate k9.4036 N/mm
Working force F112.84 N
Working shear stress τ209.01 MPa
First axial surge frequency205.38 Hz
Spring index C7.4286
Wahl factor K_w1.1995
Total coils Nₜ11
Solid height Lₛ38.5 mm
Working length L₀ − y58 mm
Travel to solid31.5 mm
Working clearance to solid19.5 mm
Force at solid height296.21 N
Estimated stress at solid548.65 MPa
Free slenderness L₀/D2.6923
Absolute stability L₀/D limit5.1973
Critical buckling travel—

Starting result

The surge calculation uses mass. Specific weight is converted with standard gravity before calculating frequency.

Axial spring rate k
9.4036 N/mm
First axial surge frequency
205.38 Hz
Solid height Lₛ
38.5 mm

Model and assumptions

k = Gd⁴/(8D³Nₐ) · τ = K_w·8FD/(πd³) · f₁ = ½√(k/mₐ) for seated ends

Round wire and a linear rate up to solid. Buckling uses Wahl–Haringx lateral stability with the selected end restraint. Fixed–fixed assumes restrained seats. Surge uses active wire mass, with the fixed–free frequency halved.

References and calculation method