ASME V Article 2 · Ug screen

X-ray tube with twice the reference SFD

A cabinet technique moves from 250 mm to 500 mm with fixed tube output, object and detector.

Reading the result. Doubling SFD multiplies the reference exposure time by four. No radioactive decay term is applied.

Setup

Exposure geometry

mm
mm
Film-side surface in contact.
mm

Reference shot

mm
min
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Calculated Ug
0.016667mm
ASME Ug limit
0.508mm
Minimum SFD
35.748mm
Exposure time
3min
Pass · within Ug limit

This verdict covers the geometric unsharpness screen only.

Focal spot projection onto filmObject is assumed in contact with the film or detector. The shaded band represents geometric penumbra.Radiographic setupContact geometryUg / thickness limit3.2808%Source spotObjectFilm blur
Object is assumed in contact with the film or detector. The shaded band represents geometric penumbra.
Source-to-object distance
480mm
Ug margin to limit
0.49133mm
Inverse-square time factor
4×
Source half-life
—
Decay-adjusted activity
—
Remaining activity
—
Activity correction
1×

Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references