ASME V Article 2 · Ug screen
Ir-192 seam exposure rescaled from a reference
A 38 mm joint is moved from 450 to 500 mm SFD. The original 2.5 min exposure used the reference activity and the new source has aged 32 days.
Reading the result. Distance and decay adjustments extend the exposure to about 4.17 min. The geometry screen is a separate check.
Setup
Exposure geometry
mm
mm
Film-side surface in contact.
mm
Reference shot
mm
min
GBq
Activity at the reference shot.
GBq
d
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Calculated Ug
- 0.20563mm
- ASME Ug limit
- 0.508mm
- Minimum SFD
- 225.01mm
- Exposure time
- 4.168min
Pass · within Ug limit
This verdict covers the geometric unsharpness screen only.
- Source-to-object distance
- 462mm
- Ug margin to limit
- 0.30237mm
- Inverse-square time factor
- 1.2346×
- Source half-life
- 73.83d
- Decay-adjusted activity
- 1369.9GBq
- Remaining activity
- 74.05%
- Activity correction
- 1.3504×
Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references