ASME V Article 2 · Ug screen

4 in weld with short source-to-film distance

A 4 in joint is set at 240 mm SFD with a 4 mm effective gamma-source size.

Reading the result. The 0.040 in tier still applies at exactly 4 in. The close source position puts Ug above that limit.

Setup

Exposure geometry

mm
mm
Film-side surface in contact.
mm

Reference shot

mm
min
GBq
Activity at the reference shot.
GBq
d
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Calculated Ug
2.9364mm
ASME Ug limit
1.016mm
Minimum SFD
501.6mm
Exposure time
0.71111min
Fail · exceeds ASME Ug screen

Increase SFD or review source size and film placement.

Focal spot projection onto filmObject is assumed in contact with the film or detector. The shaded band represents geometric penumbra.Radiographic setupContact geometryUg / thickness limit289.02%Source spotObjectFilm blur
Object is assumed in contact with the film or detector. The shaded band represents geometric penumbra.
Source-to-object distance
138.4mm
Ug margin to limit
-1.9204mm
Inverse-square time factor
0.28444×
Source half-life
1925.2d
Decay-adjusted activity
1850GBq
Remaining activity
100%
Activity correction
1×

Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references