ASME V Article 2 · Ug screen

Co-60 thick section after one half-life

A 114.3 mm reference geometry is repeated at the same 600 mm SFD after one Co-60 half-life.

Reading the result. With the same original activity and geometry, halve the current activity and double the reference exposure time.

Setup

Exposure geometry

mm
mm
Film-side surface in contact.
mm

Reference shot

mm
min
GBq
Activity at the reference shot.
GBq
d
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Calculated Ug
0.70599mm
ASME Ug limit
1.778mm
Minimum SFD
307.16mm
Exposure time
10min
Pass · within Ug limit

This verdict covers the geometric unsharpness screen only.

Focal spot projection onto filmObject is assumed in contact with the film or detector. The shaded band represents geometric penumbra.Radiographic setupContact geometryUg / thickness limit39.707%Source spotObjectFilm blur
Object is assumed in contact with the film or detector. The shaded band represents geometric penumbra.
Source-to-object distance
485.7mm
Ug margin to limit
1.072mm
Inverse-square time factor
1×
Source half-life
1925.2d
Decay-adjusted activity
925GBq
Remaining activity
50%
Activity correction
2×

Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references