Worked example
Full uplift with drains out of service
Review a concrete dam with an 18 m base after loss of foundation drainage. Reservoir and tailwater depths are 17.0 m and 1.5 m.
Inputs
Hydraulic readout
Within the middle third
Sliding FS: 2.0029, Overturning FS: 2.2919, Heel pressure: 240.319 kPa, Toe pressure: 161.237 kPa
Input values
- Dam height H
- 20 m
- Crest width
- 4.2 m
- Base width B
- 18 m
- Monolith width
- 1 m
- Concrete unit weight
- 23.6 kN/m³
- Reservoir depth
- 17 m
- Tailwater depth
- 1.5 m
- Uplift distribution
- Full linear uplift
- Silt depth
- 0.8 m
- Submerged silt unit weight
- 9.2 kN/m³
- Silt pressure factor Kₐ
- 0.33
- Base friction μ
- 0.72
- Base cohesion c
- 12 kPa
- Seismic coefficient kₕ
- 0
- Westergaard thrust
- Include
- Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
Calculation details
- Eccentricity toward toe
- -0.590812 m
- Kern half-width B/6
- 3 m
- Resultant from heel
- 8.40919 m
- Concrete weight
- 5,239.2 kN
- Reservoir thrust
- 1,417.06 kN
- Tailwater thrust
- 11.0325 kN
- Tailwater downward force
- 7.61241 kN
- Total uplift
- 1,632.81 kN
- Silt thrust
- 0.97152 kN
- Dam inertia
- 0 kN
- Westergaard thrust
- 0 kN
- Net vertical force
- 3,614.01 kN
- Net downstream force
- 1,407 kN
- Resisting toe moment
- 61,490.9 kN·m
- Overturning toe moment
- 26,829.6 kN·m
- Net toe moment
- 34,661.2 kN·m
Interpreting this example
The full linear uplift diagram gives the pressure resultant directly. Verify whether net vertical force and heel stress remain acceptable.
FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)
A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.
Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.
Worked examples
Open a case to load its inputs and interpretation.
- Drained gravity-dam monolithA 14.5 m base and 3.5 m crest support an 18 m monolith at normal pool. A foundation-level drain retains 52% of its undrained excess head.
- Pseudo-static earthquake load caseA 23 m concrete monolith is checked at kₕ = 0.13 with a 19 m pool and optional Westergaard loading.
- Heel tension in a slender damA preliminary 16 m tall section has a 7.2 m base, a 2.2 m crest and 14 m of reservoir depth with full uplift.
- Gravity dam with high tailwaterCheck the 18 m section with reservoir depth 15.0 m and a temporary 10 m downstream pool.