Worked example

Gravity dam with high tailwater

Check the 18 m section with reservoir depth 15.0 m and a temporary 10 m downstream pool.

Results ↓

Inputs

Monolith geometry
m
m
m
m
kN/m³
Water & uplift
m
m
Gallery parameters
1 retains the undrained excess head at the drain. 0 drains to tailwater head.
Silt, base & seismic loads
m
kN/m³
kPa

Hydraulic readout

Within the middle third

Sliding FS: 3.16554, Overturning FS: 2.12137, Heel pressure: 236.253 kPa, Toe pressure: 105.784 kPa

Gravity dam force section and foundation pressuresHydrostatic thrust diagrams, the resultant and the middle-third area are shown in section. The adjacent panel shows uplift above and bearing pressures below.SLIDING FS3.1655OVERTURN FS2.1214HEEL PRESSURE236.25 kPaTOE PRESSURE105.78 kPaMonolith and resultantThrustKernelBaseUplift & linear bearingUpliftBearingTensionResultant · middle thirde = -0.92183 m
  • Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
  • Gallery uplift assumes an effective drain at foundation level. Confirm piezometric and drainage conditions.

Calculation details

Eccentricity toward toe
-0.921829 m
Kern half-width B/6
2.41667 m
Resultant from heel
6.32817 m
Concrete weight
3,823.2 kN
Reservoir thrust
1,103.25 kN
Tailwater thrust
490.332 kN
Tailwater downward force
299.648 kN
Total uplift
1,643.08 kN
Silt thrust
6.072 kN
Dam inertia
0 kN
Westergaard thrust
0 kN
Net vertical force
2,479.77 kN
Net downstream force
618.988 kN
Resisting toe moment
38,335.1 kN·m
Overturning toe moment
18,070.9 kN·m
Net toe moment
20,264.2 kN·m

Interpreting this example

Downstream pressure resists rotation and adds a downward component on the batter. Higher toe uplift partly offsets these effects.

FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)

A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.

Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet