Channels

Hydraulic Jump & Stilling Basin Calculator

Compute conjugate depth, energy loss, dissipated power and a USBR Type II, III or IV stilling-basin screening length.

Results ↓

Inputs

Approach section
m
m
Approach flow
m³/s

Hydraulic readout

Steady hydraulic jump

Sequent depth: 3.04867 m, Head loss: 3.54641 m, Power loss: 486.897 kW, Basin length: 7.24357 m

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH3.0487 mHEAD LOSS3.5464 mPOWER LOSS486.9 kWBASIN LENGTH7.2436 mJump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained47.183%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.

Calculation details

Upstream Froude
5.47485
Jump class
Steady
Discharge
14 m³/s
Unit discharge
4.66667 m²/s
Upstream velocity
11.1111 m/s
Downstream velocity
1.53072 m/s
Jump height
2.62867 m
Energy retained
47.1832%
Natural jump length
18.4902 m
USBR basin screen
Type III

Calculation method

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

Share worksheet