Worked example

Weak jump in a test flume

A 0.7 m recirculating flume operates at Fr₁ = 2.1 with y₁ = 0.11 m.

Results ↓

Inputs

Approach section
m
m
Approach flow

Hydraulic readout

Weak hydraulic jump

Sequent depth: 0.276281 m, Head loss: 0.0378201 m, Power loss: 0.0622889 kW

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH0.27628 mHEAD LOSS0.03782 mPOWER LOSS0.062289 kWBASIN LENGTH—Jump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained89.272%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.
  • The jump is undular or weak. The Type II, III and IV selection screens begin at Fr₁ = 2.5.

Calculation details

Upstream Froude
2.1
Jump class
Weak
Discharge
0.167945 m³/s
Unit discharge
0.239921 m²/s
Upstream velocity
2.1811 m/s
Downstream velocity
0.868396 m/s
Jump height
0.166281 m
Energy retained
89.2724%
Natural jump length
1.24326 m

Interpreting this example

The conjugate depth and loss are available. The Type II, III and IV screen calls for stronger jumps than this experiment.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet