Worked example

Undular canal transition

A canal reach approaches its downstream pool at Fr₁ = 1.24, with a 0.8 m flow depth across 3.5 m.

Results ↓

Inputs

Approach section
m
m
Approach flow

Hydraulic readout

Undular hydraulic jump

Sequent depth: 1.05881 m, Head loss: 0.00511655 m, Power loss: 0.487959 kW

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH1.0588 mHEAD LOSS0.0051166 mPOWER LOSS0.48796 kWBASIN LENGTH—Jump and rollerDepth y₁Depth y₂Specific energy before / afterApproachRetainedLoss ΔEEnergy retained99.638%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.
  • The jump is undular or weak. The Type II, III and IV selection screens begin at Fr₁ = 2.5.

Calculation details

Upstream Froude
1.24
Jump class
Undular
Discharge
9.7249 m³/s
Unit discharge
2.77854 m²/s
Upstream velocity
3.47318 m/s
Downstream velocity
2.62421 m/s
Jump height
0.25881 m
Energy retained
99.6384%

Interpreting this example

The depth rise and dissipation are small. Review wave trains and freeboard instead of relying on a stilling-basin length.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet