Worked example

Type IV oscillating jump

A low drop produces Fr₁ = 3.2 over a 4.2 m floor. Incoming flow depth is 0.51 m.

Results ↓

Inputs

Approach section
m
m
Approach flow

Hydraulic readout

Oscillating hydraulic jump

Sequent depth: 2.06704 m, Head loss: 0.895201 m, Power loss: 134.572 kW, Basin length: 11.5672 m

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH2.067 mHEAD LOSS0.8952 mPOWER LOSS134.57 kWBASIN LENGTH11.567 mJump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained71.319%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.
  • Check wave suppression and a tailwater depth of roughly 1.05–1.10 times y₂.

Calculation details

Upstream Froude
3.2
Jump class
Oscillating
Discharge
15.329 m³/s
Unit discharge
3.64977 m²/s
Upstream velocity
7.15641 m/s
Downstream velocity
1.7657 m/s
Jump height
1.55704 m
Energy retained
71.3187%
Natural jump length
11.5672 m
USBR basin screen
Type IV

Interpreting this example

Use the Type IV length as an initial envelope. An oscillating jump needs a separate downstream wave and tailwater check.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

All cases →