A 35 m floor with shallow cutoffs was assessed under a 2.95 m head. Select the project’s conservative 8.5 creep requirement.

Results ↓

Inputs

Flow net
m
m/s
m
Foundation geometry
m
m
m
Material

Hydraulic readout

Both seepage screens pass

Unit seepage: 1.63889e-5 m²/s, Lane ratio: 9.51412, Exit gradient: 0.180098, Boiling FS: 5.51909

Foundation seepage and exit-gradient screensThe illustrative flow net wraps under the cutoff walls. Right-hand bars compare the exit gradient and weighted creep ratio with their screening thresholds.UNIT SEEPAGE1.6389e-5 m²/sLANE RATIO9.5141EXIT GRADIENT0.1801BOILING FS5.5191Cutoffs & schematic flow netFlowlinesDropsExitPiping and creep checksExit / critical gradientLane / material limitThresholdPassReviewExit gradient safety factor5.5191 / 4.0
  • Use an independently drawn flow net for homogeneous, isotropic seepage. Lane’s ratio screens empirical piping progression.
  • This option uses the conservative 8.5 threshold. Lane’s published fine-sand row uses 7.0.

Calculation details

Lane material threshold
8.5
Critical gradient
0.993976
Target boiling factor
4
Mean floor head gradient
0.0842857
Head drop per element
0.163889 m
Heel uplift above tailwater
28.9296 kPa
Horizontal creep
35 m
Vertical creep
16.4 m

Interpreting this example

Compare the project screen with the historical fine-sand row. Verify that the exit spacing was measured normal to the last equipotentials.

q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ

The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.