Worked example

Measured foundation creep path

As-built dimensions give 31 m of horizontal path and 15 m of vertical path through a medium-sand foundation.

Results ↓

Inputs

Flow net
m
m/s
m
Foundation geometry
m
m
m
Measured creep lengths
m
m
Material

Hydraulic readout

Both seepage screens pass

Unit seepage: 1.78947e-5 m²/s, Lane ratio: 7.45098, Exit gradient: 0.220923, Boiling FS: 4.4992

Foundation seepage and exit-gradient screensThe illustrative flow net wraps under the cutoff walls. Right-hand bars compare the exit gradient and weighted creep ratio with their screening thresholds.UNIT SEEPAGE1.7895e-5 m²/sLANE RATIO7.451EXIT GRADIENT0.22092BOILING FS4.4992Cutoffs & schematic flow netFlowlinesDropsExitPiping and creep checksExit / critical gradientLane / material limitThresholdPassReviewExit gradient safety factor4.4992 / 4.0
  • Use an independently drawn flow net for homogeneous, isotropic seepage. Lane’s ratio screens empirical piping progression.

Calculation details

Lane material threshold
6
Critical gradient
0.993976
Target boiling factor
4
Mean floor head gradient
0.121429
Head drop per element
0.178947 m
Heel uplift above tailwater
33.3426 kPa
Horizontal creep
31 m
Vertical creep
15 m

Interpreting this example

Use manual creep lengths to include geometry absent from the simple two-cutoff sketch. The independent flow net still sets unit seepage.

q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ

The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.

The USBR 4.0 exit-gradient screen is for cohesionless quick conditions in new or remedial dam work. Filters, uplift, stratification, anisotropy and concentrated leakage require separate checks.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet