Worked example

Broad-crested river control

A 4 m control crest has 0.64 m upstream head, 0.48 m downstream head and a specified critical-flow factor of 0.96.

Results ↓

Inputs

Measuring device
m
For Parshall flumes use the standard Hₐ tap.
m
Above crest for weirs or Hᵦ at the flume tap. Enter 0 for no positive downstream head.
Crest dimensions
m
Broad-crest factor
Dimensionless multiplier on critical-flow discharge (0 < Cᵈ ≤ 1).

Hydraulic readout

Above the tailwater screen

Free discharge: 3.35139 m³/s, Villemonte Q: 2.23831 m³/s, Submergence ratio: 75%, Comparison limit: 60%

Measuring structure geometry and free ratingH₁ and H₂ are measured from the prescribed device datums. The rating curve shows free discharge versus upstream head.FREE FLOW3.3514 m³/sVILLEMONTE Q2.2383 m³/sSUBMERGENCE75%SCREEN LIMIT60%Measuring crestHead H₁Head H₂CrestFree discharge Q(H₁)RatingH₁ pointHead H₁ →Tailwater ratio75% / 60%
  • Villemonte gives a submerged-flow screen. The 60% line is a comparison threshold. Calibrate positive-tailwater conditions for the installed geometry.
  • Broad-crested rating assumes a hydrostatic critical section. Drowned ratings require a structure-specific relation.

Calculation details

Effective width
4 m
Head exponent
1.5
Villemonte multiplier
0.667876

Interpreting this example

The 75% ratio exceeds the comparison marker. The correction shows sensitivity. Use a site-specific drowned rating to estimate measured flow.

Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵

Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.

The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.