Worked example

USBR 3 ft Parshall flume

A standard 3 ft Parshall flume has Hₐ = 2.10 ft and Hᵦ = 1.89 ft, matching the head pair in the USBR correction example.

Results ↓

Inputs

Measuring device
ft
For Parshall flumes use the standard Hₐ tap.
ft
Above crest for weirs or Hᵦ at the flume tap. Enter 0 for no positive downstream head.
Flume calibration

Hydraulic readout

Above Parshall modular limit

Free discharge: 38.465 cfs, Villemonte Q: 18.6457 cfs, Submergence ratio: 90%, Comparison limit: 70%

Measuring structure geometry and free ratingH₁ and H₂ are measured from the prescribed device datums. The rating curve shows free discharge versus upstream head.FREE FLOW38.465 cfsVILLEMONTE Q18.646 cfsSUBMERGENCE90%SCREEN LIMIT70%Parshall flume profileHead H₁Head H₂CrestFree discharge Q(H₁)RatingH₁ pointHead H₁ →Tailwater ratio90% / 70%
  • Use H₁ = Hₐ and H₂ = Hᵦ at the prescribed taps. Villemonte is a sensitivity estimate only. Apply the USBR flume-specific correction chart above 70%.

Calculation details

Effective width
3 ft
Head exponent
1.57
Villemonte multiplier
0.484746
Parshall calibration K (ft/cfs basis)
12

Interpreting this example

The free-flow rating is about 38.4 cfs. At 90% submergence, USBR Figure 8-16 gives a 3.5 cfs correction times 2.4, for 30.0 cfs. Use the Villemonte value for sensitivity only.

Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵

Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.

The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.