Light cap with laminar cooling flow

A small shot creates a low thermal load across two large cooling channels.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Review calculations ↑
Cooling time
2.36s
Heat load
0.13kW
Coolant flow
0.37L/min
Channel Re
440

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNELS2.36 sØ 11 mmMelt 205 °CEject 95 °C

Laminar channel flow

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent0.04 TR
Resin enthalpy removed203.5 kJ/kg
Heat removed per shot5.09 kJ
Flow per parallel circuit0.18 L/min
Channel mean velocity0.03 m/s
Cycle time minus cooling37.64 s
Re margin above 4,000-3,560

Working through the example

The heat balance calls for little flow, which leaves the channel short of the turbulence target.

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.