Cooling time 2.36 s
Heat load 0.13 kW
Coolant flow 0.37 L/min
Channel Re 440
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 2.36 s Ø 11 mm Melt 205 °C Eject 95 °C
Laminar channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.04 TR Resin enthalpy removed 203.5 kJ/kg Heat removed per shot 5.09 kJ Flow per parallel circuit 0.18 L/min Channel mean velocity 0.03 m/s Cycle time minus cooling 37.64 s Re margin above 4,000 -3,560
Working through the example
The heat balance calls for little flow, which leaves the channel short of the turbulence target.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 1.4 mm Resin thermal diffusivity 0.115 mm²/s Melt temperature 205 °C Ejection temperature 95 °C Mold wall temperature 42 °C Part and runner mass per shot 0.025 kg Total cycle time 40 s Resin specific heat 1.85 kJ/(kg·K) Latent heat released 0 kJ/kg Channel inner diameter 11 mm Equal-flow parallel circuits 2 Allowable coolant temperature rise 5 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 2.36 s Heat load 0.13 kW Coolant flow 0.37 L/min Channel Re 440 Refrigeration equivalent 0.04 TR Resin enthalpy removed 203.5 kJ/kg Heat removed per shot 5.09 kJ Flow per parallel circuit 0.18 L/min Channel mean velocity 0.03 m/s Cycle time minus cooling 37.64 s Re margin above 4,000 -3,560
Laminar channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 2.36 s Ø 11 mm Melt 205 °C Eject 95 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.