Cooling time 13.16 s
Heat load 2.36 kW
Coolant flow 11.31 L/min
Channel Re 18,694
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 13.16 s Ø 8 mm Melt 240 °C Eject 96 °C
Turbulent channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.67 TR Resin enthalpy removed 266.4 kJ/kg Heat removed per shot 61.27 kJ Flow per parallel circuit 5.65 L/min Channel mean velocity 1.87 m/s Cycle time minus cooling 12.84 s Re margin above 4,000 14,694
Model and assumptions
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 3 mm Resin thermal diffusivity 0.115 mm²/s Melt temperature 240 °C Ejection temperature 96 °C Mold wall temperature 50 °C Part and runner mass per shot 0.23 kg Total cycle time 26 s Resin specific heat 1.85 kJ/(kg·K) Latent heat released 0 kJ/kg Channel inner diameter 8 mm Equal-flow parallel circuits 2 Allowable coolant temperature rise 3 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 13.16 s Heat load 2.36 kW Coolant flow 11.31 L/min Channel Re 18,694 Refrigeration equivalent 0.67 TR Resin enthalpy removed 266.4 kJ/kg Heat removed per shot 61.27 kJ Flow per parallel circuit 5.65 L/min Channel mean velocity 1.87 m/s Cycle time minus cooling 12.84 s Re margin above 4,000 14,694
Turbulent channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 13.16 s Ø 8 mm Melt 240 °C Eject 96 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.