Cooling time 7.7 s
Heat load 5.91 kW
Coolant flow 21.26 L/min
Channel Re 28,115
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 7.7 s Ø 10 mm Melt 218 °C Eject 87 °C
Turbulent channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 1.68 TR Resin enthalpy removed 342 kJ/kg Heat removed per shot 129.96 kJ Flow per parallel circuit 10.63 L/min Channel mean velocity 2.26 m/s Cycle time minus cooling 14.3 s Re margin above 4,000 24,115
Working through the example
Add the crystallization term to sensible enthalpy before sizing water flow. The slab model still uses the entered effective diffusivity.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 2.6 mm Resin thermal diffusivity 0.14 mm²/s Melt temperature 218 °C Ejection temperature 87 °C Mold wall temperature 40 °C Part and runner mass per shot 0.38 kg Total cycle time 22 s Resin specific heat 2 kJ/(kg·K) Latent heat released 80 kJ/kg Channel inner diameter 10 mm Equal-flow parallel circuits 2 Allowable coolant temperature rise 4 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 7.7 s Heat load 5.91 kW Coolant flow 21.26 L/min Channel Re 28,115 Refrigeration equivalent 1.68 TR Resin enthalpy removed 342 kJ/kg Heat removed per shot 129.96 kJ Flow per parallel circuit 10.63 L/min Channel mean velocity 2.26 m/s Cycle time minus cooling 14.3 s Re margin above 4,000 24,115
Turbulent channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 7.7 s Ø 10 mm Melt 218 °C Eject 87 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.