PP latch with heat of crystallization

The heat balance includes 80 kJ/kg released as the semicrystalline PP solidifies.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Review calculations ↑
Cooling time
7.7s
Heat load
5.91kW
Coolant flow
21.26L/min
Channel Re
28,115

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNELS7.7 sØ 10 mmMelt 218 °CEject 87 °C

Turbulent channel flow

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent1.68 TR
Resin enthalpy removed342 kJ/kg
Heat removed per shot129.96 kJ
Flow per parallel circuit10.63 L/min
Channel mean velocity2.26 m/s
Cycle time minus cooling14.3 s
Re margin above 4,00024,115

Working through the example

Add the crystallization term to sensible enthalpy before sizing water flow. The slab model still uses the entered effective diffusivity.

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.

Methodology and sources