Thick PC lens exceeds cycle allowance

A thick optical section restricts how soon the center can reach the ejection temperature.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Review calculations ↑
Cooling time
63.04s
Heat load
2.69kW
Coolant flow
12.9L/min
Channel Re
21,315

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNELS63.04 sØ 8 mmMelt 305 °CEject 125 °C

Cooling time exceeds cycle

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent0.76 TR
Resin enthalpy removed342 kJ/kg
Heat removed per shot112.86 kJ
Flow per parallel circuit6.45 L/min
Channel mean velocity2.14 m/s
Cycle time minus cooling-21.04 s
Re margin above 4,00017,315

Working through the example

Cooling time grows with squared wall thickness. A turbulent channel does not make the entered cycle long enough.

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.