Cooling time 63.04 s
Heat load 2.69 kW
Coolant flow 12.9 L/min
Channel Re 21,315
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 63.04 s Ø 8 mm Melt 305 °C Eject 125 °C
Cooling time exceeds cycle
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.76 TR Resin enthalpy removed 342 kJ/kg Heat removed per shot 112.86 kJ Flow per parallel circuit 6.45 L/min Channel mean velocity 2.14 m/s Cycle time minus cooling -21.04 s Re margin above 4,000 17,315
Working through the example
Cooling time grows with squared wall thickness. A turbulent channel does not make the entered cycle long enough.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 5.5 mm Resin thermal diffusivity 0.1 mm²/s Melt temperature 305 °C Ejection temperature 125 °C Mold wall temperature 90 °C Part and runner mass per shot 0.33 kg Total cycle time 42 s Resin specific heat 1.9 kJ/(kg·K) Latent heat released 0 kJ/kg Channel inner diameter 8 mm Equal-flow parallel circuits 2 Allowable coolant temperature rise 3 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 63.04 s Heat load 2.69 kW Coolant flow 12.9 L/min Channel Re 21,315 Refrigeration equivalent 0.76 TR Resin enthalpy removed 342 kJ/kg Heat removed per shot 112.86 kJ Flow per parallel circuit 6.45 L/min Channel mean velocity 2.14 m/s Cycle time minus cooling -21.04 s Re margin above 4,000 17,315
Cooling time exceeds cycle. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 63.04 s Ø 8 mm Melt 305 °C Eject 125 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.