Cooling time 9.31 s
Heat load 2.42 kW
Coolant flow 11.62 L/min
Channel Re 34,155
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNEL 9.31 s Ø 9 mm Melt 270 °C Eject 133 °C
Turbulent channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.69 TR Resin enthalpy removed 290.64 kJ/kg Heat removed per shot 87.19 kJ Flow per parallel circuit 11.62 L/min Channel mean velocity 3.05 m/s Cycle time minus cooling 26.69 s Re margin above 4,000 30,155
Working through the example
All flow goes through the same channel for the velocity and Reynolds calculation.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 3.3 mm Resin thermal diffusivity 0.18 mm²/s Melt temperature 270 °C Ejection temperature 133 °C Mold wall temperature 80 °C Part and runner mass per shot 0.3 kg Total cycle time 36 s Resin specific heat 1.72 kJ/(kg·K) Latent heat released 55 kJ/kg Channel inner diameter 9 mm Equal-flow parallel circuits 1 Allowable coolant temperature rise 3 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 9.31 s Heat load 2.42 kW Coolant flow 11.62 L/min Channel Re 34,155 Refrigeration equivalent 0.69 TR Resin enthalpy removed 290.64 kJ/kg Heat removed per shot 87.19 kJ Flow per parallel circuit 11.62 L/min Channel mean velocity 3.05 m/s Cycle time minus cooling 26.69 s Re margin above 4,000 30,155
Turbulent channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNEL 9.31 s Ø 9 mm Melt 270 °C Eject 133 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.