Single-circuit cooling load

A single 9 mm water path carries all flow calculated from a glass-filled nylon trial.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Review calculations ↑
Cooling time
9.31s
Heat load
2.42kW
Coolant flow
11.62L/min
Channel Re
34,155

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNEL9.31 sØ 9 mmMelt 270 °CEject 133 °C

Turbulent channel flow

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent0.69 TR
Resin enthalpy removed290.64 kJ/kg
Heat removed per shot87.19 kJ
Flow per parallel circuit11.62 L/min
Channel mean velocity3.05 m/s
Cycle time minus cooling26.69 s
Re margin above 4,00030,155

Working through the example

All flow goes through the same channel for the velocity and Reynolds calculation.

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.

Methodology and sources