Calculation methodology
Equations, input conventions, and limits for the eight molding calculators.
Units and thresholds
All calculations use a common SI state. The US view converts dimensions, areas, volumes, force, temperatures, flow, and prices at the input and output. A US ton is 2,000 lbf and a metric tonne-force is 9.80665 kN. US GPM uses a 3.785411784-liter gallon. A refrigeration ton is 3.51685 kW. Temperature differences use the scale factor alone.
Reported values are rounded for reading. Screening uses the unrounded comparison. Each result applies to the entered model. Confirm critical press, resin, and tooling settings with machine data, material guidance, and process trials.
Clamp tonnage
A_proj = N × A_part + A_runner. F_required (kN) = 0.1 × A_proj (cm²) × P_cavity (MPa) × SF.
Use the silhouette in the clamp direction, including the projected feed system. Enter mean cavity pressure at the limiting fill or packing condition. The pressure tiers are starting estimates. Use a measured or simulated cavity pressure for press selection when available. The utilization boundary compares the calculated force with the entered rating.
Open calculatorShot weight & stroke
m_shot = N × m_part + m_runner. V_melt = m_shot/ρ_melt. S_dose = 1000V_melt/(πD²/4) with cm³ and mm.
The barrel rating is geometric swept volume. Utilization counts the dose only, with 20–80% inclusive. Add the target cushion separately for the travel check. The solid-density result gives an equivalent room-temperature volume. Material and machine limits can narrow the screening window.
Open calculatorBarrel residence
V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.
Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.
Open calculatorCooling time & load
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Open calculatorGate & runner shear
Round γ_app = 32Q/(πD³), correction (3n+1)/(4n). Slit γ_app = 6Q/(wh²), correction (2n+1)/(3n). η = Kγ_w^(n−1).
Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.
Open calculatorShrinkage & steel
Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.
Open calculatorDraft & texture
Taper = H × tan(θ). Tip thickness = base thickness − taper inward or base thickness + taper outward. Custom θ_min = θ_base + Rₜ/25 µm per degree.
The calculation models a single drafted wall against a fixed datum. Preset values are screening allowances, including a zero-degree mirror geometry reference. For actual ejection, confirm positive draft, texture depth, part material, tool direction and the surface supplier's allowance.
Open calculatorCycle cost & output
Good parts/h = 3600 × N × (1−scrap)/t_cycle. Tooling per part = CapEx/quantity. Payback parts = ceil[CapEx/(price − variable cost)].
Enter distinct cycle stages, counting only additional cooling after hold. Scrap is the average fraction of part impressions rejected. Regrind credit applies to recovered runner and rejected-part resin at the entered value fraction. Production hours are averages at steady operation. Add setup labor, downtime, packing, freight and any other quoted charges to your separate commercial estimate. Currency is USD in both measurement systems.
Open calculator