Mold cooling time and chiller load calculator

Estimate slab cooling time, shot heat removal, coolant flow, and Reynolds number per cooling circuit.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Cooling time
13.16s
Heat load
2.36kW
Coolant flow
11.31L/min
Channel Re
18,694

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNELS13.16 sØ 8 mmMelt 240 °CEject 96 °C

Turbulent channel flow

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent0.67 TR
Resin enthalpy removed266.4 kJ/kg
Heat removed per shot61.27 kJ
Flow per parallel circuit5.65 L/min
Channel mean velocity1.87 m/s
Cycle time minus cooling12.84 s
Re margin above 4,00014,694

Model and assumptions

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.

Methodology and sources