Worked example

Salt Cell Percent Setting for an 18,000-Gallon Pool Running 12 Hours

A fixed 12-hour pump schedule leaves half a day of potential generation. Divide the daily chlorine requirement by what the cell could make over those 12 hours at full output.

Jump to results

Example readings

Salinity
US gal
ppm
ppm
Salt chlorine generator
lb Cl₂/day
Rating for 24 hours at full output.
ppm/day
%
hr/day

Results

Estimate

Runtime at entered setting
12.52 hr/day
Setting for entered runtime
46.9 %
Daily chlorine needed
0.38 lb Cl₂/day
Output at entered schedule
2.4 ppm/day
Salt to add
0 lb
40 lb bags
0 bags
20 kg bags
0 bags
Salinity and cell output
Salinity3,200 → 3,200 ppm04,000FC output → daily demand2.4 → 2.5 ppm/day03

Export & share

Worked calculation

  1. Raise salinity by 0 ppm. 68,137 L × 0 mg/L ÷ 1,000,000 = 0 kg salt.
  2. 0 lb ÷ 40 lb per bag = 0 bags. 0 kg ÷ 20 kg per bag = 0 bags.
  3. Daily FC loss requires 0.376 lb Cl₂/day. Multiply the rated 1.6 lb/day by runtime ÷ 24 and duty ÷ 100 to get actual output.
  4. With the entered 12 hr/day and 45% setting, the model produces 2.4 ppm FC per day.
  • Compare salt with a separate salinity test and use the cell manufacturer’s limits. A larger addition or unfamiliar reading calls for staged additions and a retest after circulation.

Common questions

How do I set a controller that only changes in five-point steps?

Use the estimate as a starting point and follow the manual. Watch the tested FC trend after a change and adjust in supported steps.

What if the pump runs 12 hours but the cell is idle part of that time?

Enter the actual hours with adequate flow and cell availability. A shorter effective schedule needs a higher duty percentage for the same output.