Worked example

Salt Cell Run Time for 25,000 Gallons and 2 ppm Daily Loss

Use a measured daily FC loss separated from any known dosing. A 1.45 lb/day nameplate rating assumes continuous operation at full output; 60% reduces production per hour of pump time.

Jump to results

Example readings

Salinity
US gal
ppm
ppm
Salt chlorine generator
lb Cl₂/day
Rating for 24 hours at full output.
ppm/day
%
hr/day

Results

Estimate

Runtime at entered setting
11.51 hr/day
Setting for entered runtime
57.6 %
Daily chlorine needed
0.42 lb Cl₂/day
Output at entered schedule
2.08 ppm/day
Salt to add
0 lb
40 lb bags
0 bags
20 kg bags
0 bags
Salinity and cell output
Salinity3,200 → 3,200 ppm04,000FC output → daily demand2.1 → 2 ppm/day03

Export & share

Worked calculation

  1. Raise salinity by 0 ppm. 94,635 L × 0 mg/L ÷ 1,000,000 = 0 kg salt.
  2. 0 lb ÷ 40 lb per bag = 0 bags. 0 kg ÷ 20 kg per bag = 0 bags.
  3. Daily FC loss requires 0.417 lb Cl₂/day. Multiply the rated 1.45 lb/day by runtime ÷ 24 and duty ÷ 100 to get actual output.
  4. With the entered 12 hr/day and 60% setting, the model produces 2.08 ppm FC per day.
  • Compare salt with a separate salinity test and use the cell manufacturer’s limits. A larger addition or unfamiliar reading calls for staged additions and a retest after circulation.

Common questions

Is a 1.45 lb/day cell producing that much during a 12-hour run?

Only a 24-hour run at 100% matches the nameplate assumption. Both runtime and percentage reduce the output from that figure.

How do I verify the 2 ppm daily chlorine-loss assumption?

Measure FC at comparable times under similar conditions, accounting for feeder additions and weather. Check that the estimate matches several days of observed demand.

Method and safety references