Worked example

40 lb Salt Bags for 20,000 Gallons, 2,400 to 3,200 ppm

The salt cell is suited to 3,200 ppm in this example. The independent salinity test reads 2,400 ppm. Use the 800 ppm gap to find product weight and plan around fractional bags.

Jump to results

Example readings

Salinity
US gal
ppm
ppm
Salt chlorine generator
lb Cl₂/day
Rating for 24 hours at full output.
ppm/day
%
hr/day

Results

Estimate

Salt to add
133.53 lb
40 lb bags
3.34 bags
20 kg bags
3.03 bags
Runtime at entered setting
8.18 hr/day
Setting for entered runtime
57.2 %
Daily chlorine needed
0.33 lb Cl₂/day
Output at entered schedule
2.45 ppm/day
Salinity and cell output
Salinity2,400 → 3,200 ppm04,000FC output → daily demand2.4 → 2 ppm/day03

Export & share

Worked calculation

  1. Raise salinity by 800 ppm. 75,708 L × 800 mg/L ÷ 1,000,000 = 60.57 kg salt.
  2. 133.53 lb ÷ 40 lb per bag = 3.34 bags. 60.57 kg ÷ 20 kg per bag = 3.03 bags.
  3. Daily FC loss requires 0.334 lb Cl₂/day. Multiply the rated 1.4 lb/day by runtime ÷ 24 and duty ÷ 100 to get actual output.
  4. With the entered 10 hr/day and 70% setting, the model produces 2.45 ppm FC per day.
  • Compare salt with a separate salinity test and use the cell manufacturer’s limits. A larger addition or unfamiliar reading calls for staged additions and a retest after circulation.

Common questions

Should I round 3.34 forty-pound bags up when adding salt?

Use the calculated weight, account for the product directions and add in stages. Rounding up whole bags raises salinity beyond the modeled target.

Why check a separate salt test instead of relying on the cell display?

A cell estimate can vary with temperature, cleanliness or calibration. An independent test helps verify the starting reading before any large addition.

Method and safety references