Salt systems & spas
Saltwater Pool Salt Bags and SWG Runtime Calculator
Use a salinity test and your salt cell’s current operating target for the salt estimate. Add the chlorine nameplate rate and measured daily FC loss to estimate runtime or percent output.
Your readings
Results
Estimate- Salt to add
- 133.53 lb
- 40 lb bags
- 3.34 bags
- 20 kg bags
- 3.03 bags
- Runtime at entered setting
- 8.18 hr/day
- Setting for entered runtime
- 57.2 %
- Daily chlorine needed
- 0.33 lb Cl₂/day
- Output at entered schedule
- 2.45 ppm/day
Export & share
How the calculation works
- Raise salinity by 800 ppm. 75,708 L × 800 mg/L ÷ 1,000,000 = 60.57 kg salt.
- 133.53 lb ÷ 40 lb per bag = 3.34 bags. 60.57 kg ÷ 20 kg per bag = 3.03 bags.
- Daily FC loss requires 0.334 lb Cl₂/day. Multiply the rated 1.4 lb/day by runtime ÷ 24 and duty ÷ 100 to get actual output.
- With the entered 10 hr/day and 70% setting, the model produces 2.45 ppm FC per day.
- Compare salt with a separate salinity test and use the cell manufacturer’s limits. A larger addition or unfamiliar reading calls for staged additions and a retest after circulation.
Common questions
Why are the 40 lb and 20 kg salt bag counts different?
A 40 lb bag contains about 18.14 kg. The calculator divides the same total mass by each package size and shows fractional bags.
What does 100% mean on a salt chlorine generator?
The estimate assumes the cell produces continuously at its rated rate while the pump and cell can run. Flow, temperature and cell condition can reduce real output.