5 V to 1.2 V point-of-load buck

A 1 MHz point-of-load stage uses a 0.56 µH inductor and two paralleled ceramic banks.

Design inputs

Operating point
Inductor & output capacitor

Peak-to-peak ripple divided by average current in CCM.

Enter 0 to use the calculated inductance.

View live readout ↑

Live readout

Edit inputs
Target L
0.4908 µH
Ripple ΔI
1.578 A
Peak Iₗ
6.789 A
Ripple ΔV
5.396 mV
Inductor current Inductor current 1 µs / period Iₗ0Switching cycle →Peak current6.79 ARipple ΔI1.58 ARegionCCM
The trace follows the selected inductor. The idle interval opens when coil current reaches zero before the next cycle.
Continuous conduction

Output ripple is within the entered goal.

CCM boundary / load0.7889 A / 6 A

Output ripple / goal5.396 mV / 14 mV

Result breakdown
Inductance at target ripple0.490842 µH
Inductance used in readout0.56 µH
Continuous-conduction duty26.3736 %
Operating duty26.3736 %
Conduction modeCCM
Average inductor current6 A
Valley inductor current5.21115 A
Peak inductor current6.78885 A
RMS inductor current6.01726 A
Peak-to-peak inductor ripple1.57771 A
Critical output load0.788854 A
Capacitive ripple2.24106 mV
ESR ripple3.15542 mV
Combined ripple estimate5.39648 mV
Minimum capacitance at ripple goal18.1854 µF

Worked calculation

Veff = 91% × 5 V = 4.55 V → L at target ripple = 0.490842 µH

Compare ESR ripple with capacitive ripple to see which term consumes more of the budget.

Duty & inductor

Veff = η · Vin | L = Von · D / (fs · ΔIL)

Efficiency is represented by an effective input voltage ahead of an ideal switching stage. Duty is Vout/Veff for buck, 1 − Veff/Vout for boost, and Vout/(Veff + Vout) for the inverting topology. Output magnitude is positive for all three cases.

Boundary & current

Icrit = (ΔIL,CCM / 2) · k | k = 1 (buck), 1 − D (boost / inverting)

At the boundary, the valley inductor current is zero. Below it, the model solves on-time and off-time from the two current slopes and load charge balance. For CCM the RMS value is √(Iavg² + ΔIL²/12).

Ripple budget

ΔVpp ≈ Qpositive / Cout + ESR · ΔIcap

Positive capacitor current is integrated over the waveform. For a CCM buck this yields ΔIL/(8·fs·Cout). CCM boost and inverting stages reduce to Iout·D/(fs·Cout) when coil current during discharge stays above load current. Use effective capacitance under DC bias.