12 V to −5 V inverting rail

A compact auxiliary inverter supplies a −5 V rail with 44 µF of effective output capacitance.

Design inputs

Operating point
Inductor & output capacitor

Peak-to-peak ripple divided by average current in CCM.

Enter 0 to use the calculated inductance.

View live readout ↑

Live readout

Edit inputs
Target L
8.723 µH
Ripple ΔI
0.8841 A
Peak Iₗ
2.652 A
Ripple ΔV
43.46 mV
Inductor current Inductor current 2.27 µs / period Iₗ0Switching cycle →Peak current2.65 ARipple ΔI0.884 ARegionCCM
The trace follows the selected inductor. The idle interval opens when coil current reaches zero before the next cycle.
Continuous conduction

Output ripple is within the entered goal.

CCM boundary / load0.3 A / 1.5 A

Output ripple / goal43.46 mV / 70 mV

Result breakdown
Inductance at target ripple8.72318 µH
Inductance used in readout8.72318 µH
Continuous-conduction duty32.1337 %
Operating duty32.1337 %
Conduction modeCCM
Average inductor current2.21023 A
Valley inductor current1.76818 A
Peak inductor current2.65227 A
RMS inductor current2.22491 A
Peak-to-peak inductor ripple0.884091 A
Critical output load0.3 A
Capacitive ripple24.897 mV
ESR ripple18.5659 mV
Combined ripple estimate43.4629 mV
Minimum capacitance at ripple goal21.2984 µF

Worked calculation

Veff = 88% × 12 V = 10.56 V → L at target ripple = 8.72318 µH

Change ESR while holding capacitance fixed. Once ESR consumes the ripple goal, increasing capacitance alone cannot meet it.

Duty & inductor

Veff = η · Vin | L = Von · D / (fs · ΔIL)

Efficiency is represented by an effective input voltage ahead of an ideal switching stage. Duty is Vout/Veff for buck, 1 − Veff/Vout for boost, and Vout/(Veff + Vout) for the inverting topology. Output magnitude is positive for all three cases.

Boundary & current

Icrit = (ΔIL,CCM / 2) · k | k = 1 (buck), 1 − D (boost / inverting)

At the boundary, the valley inductor current is zero. Below it, the model solves on-time and off-time from the two current slopes and load charge balance. For CCM the RMS value is √(Iavg² + ΔIL²/12).

Ripple budget

ΔVpp ≈ Qpositive / Cout + ESR · ΔIcap

Positive capacitor current is integrated over the waveform. For a CCM buck this yields ΔIL/(8·fs·Cout). CCM boost and inverting stages reduce to Iout·D/(fs·Cout) when coil current during discharge stays above load current. Use effective capacitance under DC bias.