The shaded wedges represent the triangular overlap loss model. Time is expanded around the edges to show rise and fall.
Device headroom available
The device heat total excludes gate-drive power. Recovery heat may be split between devices.
Drain stress / rating445 V / 650 V
Junction / ceiling100 °C / 150 °C
Result breakdown
Hot on-resistance
134.48 mΩ
Channel conduction
1.02006 W
Switching overlap
2.1 W
Output capacitance
1 W
Reverse recovery
0.72 W
Dead-time diode conduction
0.02898 W
Modeled device-side loss
4.86904 W
Gate-drive supply power
0.0384 W
Combined modeled loss
4.90744 W
Initial gate drive current estimate
2.4 A
Efficiency penalty vs. ideal
0.934915 pp
Efficiency with these losses only
99.0651 %
Drain stress with overshoot
445 V
Drain headroom
205 V
Operating junction temperature
100 °C
Junction headroom
50 °C
Worked calculation
Pcond = 43% × (4.2 A)² × 134.48 mΩ = 1.02006 W
The stored energy term scales linearly with switching frequency. Check the datasheet voltage at which Eoss was measured.
Channel & hard switching
Pcond = D · I² · R25 · mt | Psw = ½ · VDS · I · (tr + tf) · fs
Use the conducting current during the on interval and a datasheet hot-resistance factor. The overlap term assumes one turn-on and one turn-off per period with the stated voltage and current.
Gate & capacitance
Pgate = Qg · VGS · fs | Poutput cap = Eoss · fs
Direct datasheet Eoss at the bus voltage is preferred for nonlinear output capacitance. Qoss mode approximates Eoss as ½·VDS·Qoss and Coss mode uses ½·Coss·VDS². Initial gate current is VGS/Rloop.
Use one recovery event per period and enter total diode conduction time per cycle. Penalty is 100·Ploss/(Pout + Ploss) percentage points relative to lossless conversion. Avoid adding these terms again if using measured switching energy.
Junction estimate
Tj = Ta + Pdevice · RθJA
Use the effective resistance for the board and cooling path. The estimate holds the entered hot resistance factor constant. Check the datasheet factor at the resulting junction temperature and account for temperature-dependent feedback separately.
{"tool":{"id":"mosfet","groups":[{"title":"Switch operating point","fields":[{"key":"vds","label":"Switched drain voltage","value":48,"unit":"V","help":""},{"key":"load","label":"Conducting current","value":12,"unit":"A","help":""},{"key":"duty","label":"On duty","value":42,"unit":"%","help":""},{"key":"fs","label":"Switching frequency","value":250,"unit":"kHz","help":""},{"key":"pout","label":"Converter output power","value":240,"unit":"W","help":""},{"key":"spike","label":"Additional drain overshoot","value":8,"unit":"V","help":""}]},{"title":"Ratings & hot resistance","fields":[{"key":"ratedDrain","label":"MOSFET drain rating","value":80,"unit":"V","help":""},{"key":"temperatureMode","label":"Junction temperature input","value":"entered","options":[["entered","Enter operating junction"],["estimated","Estimate from thermal resistance"]]},{"key":"tj","label":"Operating junction","value":100,"unit":"temperature","help":"","when":["temperatureMode","entered"]},{"key":"ambient","label":"Maximum ambient","value":45,"unit":"temperature","help":"","when":["temperatureMode","estimated"]},{"key":"thetaJA","label":"Effective junction → ambient RθJA","value":25,"unit":"theta","help":"","when":["temperatureMode","estimated"]},{"key":"tjMax","label":"Junction ceiling","value":150,"unit":"temperature","help":""},{"key":"coldR","label":"Cold Rᴅₛ₍ₒₙ₎","value":7.2,"unit":"mΩ","help":""},{"key":"multiplier","label":"Hot resistance factor","value":1.55,"unit":"×","help":"Use the datasheet factor at the expected junction temperature."}]},{"title":"Edges & gate drive","fields":[{"key":"tr","label":"Turn-on overlap","value":16,"unit":"ns","help":""},{"key":"tf","label":"Turn-off overlap","value":22,"unit":"ns","help":""},{"key":"qg","label":"Total gate charge","value":42,"unit":"nC","help":""},{"key":"vgs","label":"Gate drive swing","value":10,"unit":"V","help":""},{"key":"gateR","label":"Total gate loop resistance","value":5,"unit":"Ω","help":"Use driver, external and internal series resistance for the edge being screened."}]},{"title":"Capacitance & diode","fields":[{"key":"capMode","label":"Output capacitance model","value":"charge","options":[["charge","Charge Qoss (linear estimate)"],["capacitance","Effective capacitance Coss"],["energy","Datasheet energy Eoss"]]},{"key":"qoss","label":"Output charge Qₒₛₛ","value":31,"unit":"nC","help":"","when":["capMode","charge"]},{"key":"coss","label":"Effective output capacitance","value":650,"unit":"pF","help":"","when":["capMode","capacitance"]},{"key":"eoss","label":"Output stored energy","value":0.74,"unit":"µJ","help":"","when":["capMode","energy"]},{"key":"qrr","label":"Reverse-recovery charge","value":22,"unit":"nC","help":""},{"key":"vsd","label":"Body-diode drop","value":0.85,"unit":"V","help":""},{"key":"dead","label":"Total dead time per cycle","value":60,"unit":"ns","help":""}]}],"cards":[["total","Total loss"],["switching","Overlap loss"],["conduction","Ohmic loss"],["peakGate","Peak gate I"]],"rows":[["hotR","Hot on-resistance","mΩ"],["conduction","Channel conduction","W"],["switching","Switching overlap","W"],["outputCap","Output capacitance","W"],["reverseRecovery","Reverse recovery","W"],["diode","Dead-time diode conduction","W"],["device","Modeled device-side loss","W"],["gate","Gate-drive supply power","W"],["total","Combined modeled loss","W"],["peakGate","Initial gate drive current estimate","A"],["lossPct","Efficiency penalty vs. ideal","pp"],["efficiency","Efficiency with these losses only","%"],["drainStress","Drain stress with overshoot","V"],["vMargin","Drain headroom","V"],["tj","Operating junction temperature","temperature"],["tMargin","Junction headroom","rise"]],"caption":"The shaded wedges represent the triangular overlap loss model. Time is expanded around the edges to show rise and fall."},"title":"400 V switch with datasheet Eoss","slug":"example-mosfet-400v-eoss","defaults":{"vds":400,"load":4.2,"duty":43,"fs":100,"pout":520,"spike":45,"ratedDrain":650,"temperatureMode":"entered","tj":100,"ambient":45,"thetaJA":25,"tjMax":150,"coldR":82,"multiplier":1.64,"tr":11,"tf":14,"qg":32,"vgs":12,"gateR":5,"capMode":"energy","qoss":31,"coss":650,"eoss":10,"qrr":18,"vsd":1.15,"dead":60}}
PowerConvLab · Design worksheet
400 V switch with datasheet Eoss
Device headroom available · The device heat total excludes gate-drive power. Recovery heat may be split between devices.