6 A external trace on 1 oz copper

Size an external 42 mm power trace for a 10 °C rise goal on standard nominal foil.

Design inputs

Trace & thermal limits

Enter 0 to use the calculated width.

Copper foil
View live readout ↑

Live readout

Edit inputs
Min. width
3.556 mm
Hot resistance
6.275 mΩ
Voltage drop
37.65 mV
Trace rise
10 °C
Trace cross-section Trace cross-section External layer Routing widthSubstrateReference planeWidth3.56 mmCopper foil35 µmTrace rise10 °C
The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
At the IPC fit target

IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.

Trace rise / goal10 °C / 10 °C

Result breakdown
Minimum trace width3.55625 mm
Minimum trace width in mils140.01 mil
Trace width used in readout3.55625 mm
Minimum cross-sectional area0.124469 mm²
Cross-sectional area used0.124469 mm²
Finished copper thickness35 µm
Estimated temperature rise10 °C
Estimated copper temperature40 °C
Temperature-corrected resistance6.27461 mΩ
Voltage drop37.6476 mV
Trace dissipation0.225886 W
Temperature-rise headroom0 °C

Worked calculation

Width = 0.124469 mm² / 0.035 mm = 3.55625 mm at 10 °C rise

Toggle units to compare the routing width in mm and mil. Use the finished copper thickness for fabrication checks.

IPC-2221 fit

I = k · ΔT^0.44 · A^0.725 | A in mil²

Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.

Hot resistance

R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A

Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.

IPC-2152 context

Check stackup, nearby copper and heat spreading

This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.