The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
At the IPC fit target
IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.
Trace rise / goal5 °C / 5 °C
Result breakdown
Minimum trace width
2.73921 mm
Minimum trace width in mils
107.843 mil
Trace width used in readout
2.73921 mm
Minimum cross-sectional area
0.383489 mm²
Cross-sectional area used
0.383489 mm²
Finished copper thickness
140 µm
Estimated temperature rise
5 °C
Estimated copper temperature
60 °C
Temperature-corrected resistance
1.92484 mΩ
Voltage drop
9.6242 mV
Trace dissipation
0.048121 W
Temperature-rise headroom
0 °C
Worked calculation
Width = 0.383489 mm² / 0.14 mm = 2.73921 mm at 5 °C rise
Compare the calculated width at 5 °C and 10 °C. Check the change against the real board construction.
IPC-2221 fit
I = k · ΔT^0.44 · A^0.725 | A in mil²
Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.
Hot resistance
R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A
Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.
IPC-2152 context
Check stackup, nearby copper and heat spreading
This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.