70 MHz ringing with 150 pF test loading

The added capacitor shifts the ringing to 43 MHz. Use the exact frequency ratio with the alternate resistor estimate.

Design inputs

Scope measurements
RC selection

Sets the illustrative damped waveform and the optional resistor estimate.

View live readout ↑

Live readout

Edit inputs
Snubber R
20.17 Ω
Snubber C
272.7 pF
Resistor heat
0.0864 W
2× rating
0.1728 W
Switch-node ring-down Switch-node ring-down 57.1 ns span SWTime →Original f₀70 MHzLoaded f₁43 MHzTarget ζ0.62
The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change.
2× power target met

Verify pulse-energy rating and temperature derating on the resistor datasheet.

2× dissipation / resistor rating0.1728 W / 0.5 W

Result breakdown
Inferred parasitic capacitance90.9046 pF
Inferred parasitic inductance56.8667 nH
Characteristic impedance25.0113 Ω
Recommended snubber resistor20.1704 Ω
Recommended snubber capacitor272.714 pF
Resistor dissipation estimate0.0863958 W
Minimum resistor rating (2×)0.172792 W
Power-rating headroom0.327208 W

Worked calculation

Cpar = 150 pF / [(70 / 43)² − 1] = 90.9046 pF

Check that the resistor readout uses Z₀/(2ζ) while characteristic impedance remains fixed.

Two captures

Cpar = Ctest / [(f₀/f₁)² − 1] | Lpar = 1 / [(2πf₀)²·Cpar]

Measure the same ringing mode with and without a known parallel test capacitor. Aim for roughly half the original frequency. Nearly equal readings amplify measurement error. Using an installed resistor during the measurement shifts the result.

RC starting point

Z₀ = √(Lpar/Cpar) | Cs = multiplier · Cpar

Start with Rs = Z₀ and Cs = 3·Cpar. Z₀/(2ζ) uses the parallel-resistor approximation at the ringing frequency. The plotted target is illustrative. Component placement and the measured ring-down determine the final values.

Resistor load

Psnub ≈ Cs · Vstep² · fs

This assumes charge and discharge through the resistor each cycle. Compare twice the estimated power to the continuous rating and check repetitive pulse energy separately.