48 V switch node with a halved ringing frequency

Adding 270 pF halves the ringing frequency on a 48 V switch node.

Design inputs

Scope measurements
RC selection

Sets the illustrative damped waveform and the optional resistor estimate.

View live readout ↑

Live readout

Edit inputs
Snubber R
16.37 Ω
Snubber C
270 pF
Resistor heat
0.1742 W
2× rating
0.3484 W
Switch-node ring-down Switch-node ring-down 37 ns span SWTime →Original f₀108 MHzLoaded f₁54 MHzTarget ζ0.7
The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change.
2× power target met

Verify pulse-energy rating and temperature derating on the resistor datasheet.

2× dissipation / resistor rating0.3484 W / 0.75 W

Result breakdown
Inferred parasitic capacitance90 pF
Inferred parasitic inductance24.1296 nH
Characteristic impedance16.374 Ω
Recommended snubber resistor16.374 Ω
Recommended snubber capacitor270 pF
Resistor dissipation estimate0.174182 W
Minimum resistor rating (2×)0.348365 W
Power-rating headroom0.401635 W

Worked calculation

Cpar = 270 pF / [(108 / 54)² − 1] = 90 pF

When frequency halves, the inferred parasitic capacitance is one third of the test capacitor.

Two captures

Cpar = Ctest / [(f₀/f₁)² − 1] | Lpar = 1 / [(2πf₀)²·Cpar]

Measure the same ringing mode with and without a known parallel test capacitor. Aim for roughly half the original frequency. Nearly equal readings amplify measurement error. Using an installed resistor during the measurement shifts the result.

RC starting point

Z₀ = √(Lpar/Cpar) | Cs = multiplier · Cpar

Start with Rs = Z₀ and Cs = 3·Cpar. Z₀/(2ζ) uses the parallel-resistor approximation at the ringing frequency. The plotted target is illustrative. Component placement and the measured ring-down determine the final values.

Resistor load

Psnub ≈ Cs · Vstep² · fs

This assumes charge and discharge through the resistor each cycle. Compare twice the estimated power to the continuous rating and check repetitive pulse energy separately.