Home / RC Snubber & Ringing
Enable JavaScript to edit the preset and use exports. The preset readings are available below.
Snubber R
16.37 Ω
Snubber C
270 pF
Resistor heat
0.1742 W
2× rating
0.3484 W
Switch-node ring-down
Switch-node ring-down
37 ns span
SW Time → Original f₀ 108 MHz Loaded f₁ 54 MHz Target ζ 0.7
The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change.
2× power target met Verify pulse-energy rating and temperature derating on the resistor datasheet.
2× dissipation / resistor rating 0.3484 W / 0.75 W
Result breakdown
Inferred parasitic capacitance 90 pF Inferred parasitic inductance 24.1296 nH Characteristic impedance 16.374 Ω Recommended snubber resistor 16.374 Ω Recommended snubber capacitor 270 pF Resistor dissipation estimate 0.174182 W Minimum resistor rating (2×) 0.348365 W Power-rating headroom 0.401635 W
Worked calculation
Cpar = 270 pF / [(108 / 54)² − 1] = 90 pF
When frequency halves, the inferred parasitic capacitance is one third of the test capacitor.
Preset readings
Recommended snubber resistor 16.374 Ω
Recommended snubber capacitor 270 pF
Resistor dissipation estimate 0.174182 W
Minimum resistor rating (2×) 0.348365 W
2× power target met
{"tool":{"id":"snubber","groups":[{"title":"Scope measurements","fields":[{"key":"f0","label":"Original ringing frequency","value":96,"unit":"MHz","help":""},{"key":"f1","label":"Frequency with test cap","value":48,"unit":"MHz","help":""},{"key":"testCap","label":"Added test capacitor","value":330,"unit":"pF","help":""},{"key":"step","label":"Switch-node voltage step","value":48,"unit":"V","help":""},{"key":"fs","label":"Switching frequency","value":300,"unit":"kHz","help":""}]},{"title":"RC selection","fields":[{"key":"match","label":"Resistor method","value":"z0","options":[["z0","Match characteristic impedance"],["zeta","Use Z₀ / (2ζ) estimate"]]},{"key":"zeta","label":"Target damping ratio","value":0.7,"unit":"","help":"Sets the illustrative damped waveform and the optional resistor estimate."},{"key":"multiplier","label":"Snubber capacitance multiplier","value":3,"unit":"×","help":""},{"key":"powerRating","label":"Resistor power rating","value":1,"unit":"W","help":""}]}],"cards":[["resistance","Snubber R"],["capacitance","Snubber C"],["power","Resistor heat"],["ratedPower","2× rating"]],"rows":[["cPar","Inferred parasitic capacitance","pF"],["lPar","Inferred parasitic inductance","nH"],["z0","Characteristic impedance","Ω"],["resistance","Recommended snubber resistor","Ω"],["capacitance","Recommended snubber capacitor","pF"],["power","Resistor dissipation estimate","W"],["ratedPower","Minimum resistor rating (2×)","W"],["headroom","Power-rating headroom","W"]],"caption":"The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change."},"title":"48 V switch node with a halved ringing frequency","slug":"example-rc-snubber-half-frequency","defaults":{"f0":108,"f1":54,"testCap":270,"step":48,"fs":280,"match":"z0","zeta":0.7,"multiplier":3,"powerRating":0.75}}