ASME VIII-1 / UG-99 & UG-100

225 psig vessel proof test comparison

A 500-gallon vessel has a 225 psig MAWP, a 20 ksi test allowable and an 18.5 ksi design allowable.

Inputs

Pressure basis
psig
ksi
ksi
psig
Test media
US gal
in
lb/gal
psia

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
HYDRO TEST 316.216 psig PNEUMATIC TEST 267.568 psig WATER FILL 4165.19 lb GAS ENERGY 5250.496 kJ TEST MEDIA SECTIONS Water filledCompressed gas Entered test limit headroom PASS SCREEN 0% 100% LIMIT 150%+
317.947 psig demand / 360 psig limit

Pneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.

Export or share
Calculation breakdown
Controlling stress ratio Sₜ/Sd
1.0811
Hydrostatic multiplier
1.3
Hydrostatic gauge target
316.216 psig
Static head below gauge
1.731 psig
Hydrostatic bottom pressure
317.947 psig
Pneumatic gauge target
267.568 psig
Pneumatic absolute pressure
282.264 psia
Water fill weight
4,165.19 lb
Isentropic stored energy
5,250.496 kJ
TNT mass energy equivalence
2.7666 lb TNT eq.
Entered test limit reserve
42.053 psig
ORIGINAL PRESET

Worked calculation

A 500-gallon vessel has a 225 psig MAWP, a 20 ksi test allowable and an 18.5 ksi design allowable.

Hydrostatic gauge target
316.216 psig
Hydrostatic bottom pressure
317.947 psig
Pneumatic gauge target
267.568 psig

Multiply MAWP by the controlling stress ratio before comparing hydrostatic and pneumatic test factors. Add water head to evaluate the bottom pressure.

Calculation basis

  1. Required stress ratio

    Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.

    Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)

  2. Water and stored energy

    Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.

    Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)

  3. Check the entered limit

    The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.

    Pressure reserve = Plimit − max(Ph,bottom, Pp)

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

Sources and verification scope ↗