ASME VIII-1 / UG-99 & UG-100
Component test limit exceeded
A pressure-boundary component has a reviewed test limit of 310 psig for a vessel with 250 psig MAWP.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LivePneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.
Calculation breakdown
- Controlling stress ratio Sₜ/Sd
- 1.0811
- Hydrostatic multiplier
- 1.3
- Hydrostatic gauge target
- 351.351 psig
- Static head below gauge
- 2.164 psig
- Hydrostatic bottom pressure
- 353.515 psig
- Pneumatic gauge target
- 297.297 psig
- Pneumatic absolute pressure
- 311.993 psia
- Water fill weight
- 4,998.23 lb
- Isentropic stored energy
- 7,112.297 kJ
- TNT mass energy equivalence
- 3.7476 lb TNT eq.
- Entered test limit reserve
- -43.515 psig
Worked calculation
A pressure-boundary component has a reviewed test limit of 310 psig for a vessel with 250 psig MAWP.
- Hydrostatic bottom pressure
- 353.515 psig
- Pneumatic gauge target
- 297.297 psig
- Entered test limit reserve
- -43.515 psig
The calculated proof target exceeds the supplied component ceiling. Reconcile the test basis with the engineer responsible for the component.
Calculation basis
Required stress ratio
Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.
Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)Water and stored energy
Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.
Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)Check the entered limit
The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.
Pressure reserve = Plimit − max(Ph,bottom, Pp)
Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.