ASME VIII-1 / UG-99 & UG-100

Component test limit exceeded

A pressure-boundary component has a reviewed test limit of 310 psig for a vessel with 250 psig MAWP.

Inputs

Pressure basis
psig
ksi
ksi
psig
Test media
US gal
in
lb/gal
psia

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
HYDRO TEST 351.351 psig PNEUMATIC TEST 297.297 psig WATER FILL 4998.23 lb GAS ENERGY 7112.297 kJ TEST MEDIA SECTIONS Water filledCompressed gas Entered test limit headroom FAIL SCREEN 0% 100% LIMIT 150%+
353.515 psig demand / 310 psig limit

Pneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.

Export or share
Calculation breakdown
Controlling stress ratio Sₜ/Sd
1.0811
Hydrostatic multiplier
1.3
Hydrostatic gauge target
351.351 psig
Static head below gauge
2.164 psig
Hydrostatic bottom pressure
353.515 psig
Pneumatic gauge target
297.297 psig
Pneumatic absolute pressure
311.993 psia
Water fill weight
4,998.23 lb
Isentropic stored energy
7,112.297 kJ
TNT mass energy equivalence
3.7476 lb TNT eq.
Entered test limit reserve
-43.515 psig
ORIGINAL PRESET

Worked calculation

A pressure-boundary component has a reviewed test limit of 310 psig for a vessel with 250 psig MAWP.

Hydrostatic bottom pressure
353.515 psig
Pneumatic gauge target
297.297 psig
Entered test limit reserve
-43.515 psig

The calculated proof target exceeds the supplied component ceiling. Reconcile the test basis with the engineer responsible for the component.

Calculation basis

  1. Required stress ratio

    Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.

    Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)

  2. Water and stored energy

    Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.

    Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)

  3. Check the entered limit

    The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.

    Pressure reserve = Plimit − max(Ph,bottom, Pp)

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

Sources and verification scope ↗