ASME VIII-1 / UG-37 & UG-40
Flush nozzle with shell-only reinforcement
A thick net shell surrounds a 4-inch flush-bore nozzle with zero pad and inward projection.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveArea replacement covers one radial opening and one plane. Check all required planes, neck minimums, load paths and weld strength.
Calculation breakdown
- Base removed area d·tᵣ·F
- 1.2 in²
- Required area with strength correction
- 1.2 in²
- A₁ shell excess
- 1.8 in²
- A₂ outward nozzle excess
- 0.14 in²
- A₃ inward nozzle projection
- 0 in²
- A₄ fillet welds
- 0.0324 in²
- A₅ pad metal
- 0 in²
- Total credited area
- 1.9724 in²
- Net area balance
- 0.7724 in²
- Independent wall check
- Shell and neck meet inputs
- Nozzle outside diameter
- 4.56 in
- Creditable pad diameter limit
- 8 in
- Candidate OD at entered pad wall
- —
- Candidate wall at entered pad OD
- —
- Credited pad wall
- 0 in
- Pad sizing screen
- Pad area unnecessary
Worked calculation
A thick net shell surrounds a 4-inch flush-bore nozzle with zero pad and inward projection.
- A₁ shell excess
- 1.8 in²
- A₅ pad metal
- 0 in²
- Total credited area
- 1.9724 in²
Excess shell area can meet the replacement requirement in this case. Inward projection and pad contribute zero.
Calculation basis
Required area
Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.
A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)Eligible credit
Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.
Aavailable = A₁ + A₂ + A₃ + A₄ + A₅Pad sizing
Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.
A₅ = (ODcredited − ODneck)·tpad·fpad
Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.