ASME VIII-1 / UG-27
Corroded shell wall below requirement
A nominal 3/8-inch shell is screened against 310 psig after internal metal loss and mill undertolerance.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.4442 in
- Longitudinal pressure wall
- 0.1861 in
- Governing pressure wall
- 0.4442 in
- Minimum nominal order wall
- 0.5518 in
- Minimum new wall
- 0.3656 in
- Net corroded wall
- 0.2719 in
- Corroded inside radius
- 24.0938 in
- Circumferential MAWP
- 190.539 psig
- Longitudinal MAWP
- 453.408 psig
- Corroded MAWP
- 190.539 psig
- New-and-cold MAWP
- 269.47 psig
- Corroded pressure reserve
- -119.461 psig
- Governing stress
- Circumferential stress
Worked calculation
A nominal 3/8-inch shell is screened against 310 psig after internal metal loss and mill undertolerance.
- Minimum nominal order wall
- 0.5518 in
- Net corroded wall
- 0.2719 in
- Corroded pressure reserve
- -119.461 psig
The corroded capacity falls below the design pressure in this input case. Compare the pressure-only nominal requirement with the size entered.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.