ASME VIII-1 / UG-27

Corroded shell wall below requirement

A nominal 3/8-inch shell is screened against 310 psig after internal metal loss and mill undertolerance.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.444 in MINIMUM NOM. 0.552 in CORRODED MAWP 190.539 psig COLD MAWP 269.47 psig CYLINDRICAL WALL Net wall 0.272 inAxial loadHoop load Corroded pressure headroom FAIL SCREEN 0% 100% LIMIT 150%+
310 psig demand / 190.539 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.4442 in
Longitudinal pressure wall
0.1861 in
Governing pressure wall
0.4442 in
Minimum nominal order wall
0.5518 in
Minimum new wall
0.3656 in
Net corroded wall
0.2719 in
Corroded inside radius
24.0938 in
Circumferential MAWP
190.539 psig
Longitudinal MAWP
453.408 psig
Corroded MAWP
190.539 psig
New-and-cold MAWP
269.47 psig
Corroded pressure reserve
-119.461 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

A nominal 3/8-inch shell is screened against 310 psig after internal metal loss and mill undertolerance.

Minimum nominal order wall
0.5518 in
Net corroded wall
0.2719 in
Corroded pressure reserve
-119.461 psig

The corroded capacity falls below the design pressure in this input case. Compare the pressure-only nominal requirement with the size entered.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗