ASME VIII-1 / UG-27
Hot-service shell stress reduction
A hot vessel has a 15 ksi design allowable and a 20 ksi cold allowable. The nominal plate is 3/4 inch.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.5168 in
- Longitudinal pressure wall
- 0.2161 in
- Governing pressure wall
- 0.5168 in
- Minimum nominal order wall
- 0.6262 in
- Minimum new wall
- 0.7313 in
- Net corroded wall
- 0.6375 in
- Corroded inside radius
- 24.0938 in
- Circumferential MAWP
- 332.082 psig
- Longitudinal MAWP
- 802.265 psig
- Corroded MAWP
- 332.082 psig
- New-and-cold MAWP
- 508.67 psig
- Corroded pressure reserve
- 62.082 psig
- Governing stress
- Circumferential stress
Worked calculation
A hot vessel has a 15 ksi design allowable and a 20 ksi cold allowable. The nominal plate is 3/4 inch.
- Minimum nominal order wall
- 0.6262 in
- Corroded MAWP
- 332.082 psig
- New-and-cold MAWP
- 508.67 psig
Evaluate the corroded and ambient cases separately. The cold capacity reflects both the higher stress value and the thicker uncorroded section.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.