ASME VIII-1 / UG-27

Hot-service shell stress reduction

A hot vessel has a 15 ksi design allowable and a 20 ksi cold allowable. The nominal plate is 3/4 inch.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.517 in MINIMUM NOM. 0.626 in CORRODED MAWP 332.082 psig COLD MAWP 508.67 psig CYLINDRICAL WALL Net wall 0.638 inAxial loadHoop load Corroded pressure headroom PASS SCREEN 0% 100% LIMIT 150%+
270 psig demand / 332.082 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.5168 in
Longitudinal pressure wall
0.2161 in
Governing pressure wall
0.5168 in
Minimum nominal order wall
0.6262 in
Minimum new wall
0.7313 in
Net corroded wall
0.6375 in
Corroded inside radius
24.0938 in
Circumferential MAWP
332.082 psig
Longitudinal MAWP
802.265 psig
Corroded MAWP
332.082 psig
New-and-cold MAWP
508.67 psig
Corroded pressure reserve
62.082 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

A hot vessel has a 15 ksi design allowable and a 20 ksi cold allowable. The nominal plate is 3/4 inch.

Minimum nominal order wall
0.6262 in
Corroded MAWP
332.082 psig
New-and-cold MAWP
508.67 psig

Evaluate the corroded and ambient cases separately. The cold capacity reflects both the higher stress value and the thicker uncorroded section.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗