ASME VIII-1 / UG-27

Large-diameter shell at moderate pressure

A 120-inch-ID shell is evaluated at 120 psig with full seam efficiency and a 3/16-inch corrosion allowance.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.362 in MINIMUM NOM. 0.55 in CORRODED MAWP 144.748 psig COLD MAWP 217.391 psig CYLINDRICAL WALL Net wall 0.438 inAxial loadHoop load Corroded pressure headroom PASS SCREEN 0% 100% LIMIT 150%+
120 psig demand / 144.748 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.3624 in
Longitudinal pressure wall
0.1803 in
Governing pressure wall
0.3624 in
Minimum nominal order wall
0.5499 in
Minimum new wall
0.625 in
Net corroded wall
0.4375 in
Corroded inside radius
60.1875 in
Circumferential MAWP
144.748 psig
Longitudinal MAWP
291.606 psig
Corroded MAWP
144.748 psig
New-and-cold MAWP
217.391 psig
Corroded pressure reserve
24.748 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

A 120-inch-ID shell is evaluated at 120 psig with full seam efficiency and a 3/16-inch corrosion allowance.

Governing pressure wall
0.3624 in
Minimum nominal order wall
0.5499 in
Corroded pressure reserve
24.748 psig

The larger inside radius raises the pressure wall. Compare the corroded margin to the plate reserve before selecting an order thickness.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗