ASME B31.1 / B31.3 beam screen
Four-inch filled and insulated line
A steel process-water line carries insulation and fluid between two simple supports.
Inputs
Results
Edit inputs- Maximum span
- 15.11ft
- Mid-span sag
- 0.074in
- Line mass
- 17.88lb/ft
- Stress used
- 13.6%
Peak sag governs the calculated span. Full longitudinal stress and support loads need a separate check.
Support spacing and sag
All calculated values
| Screened support span | 15.112 ft |
|---|---|
| Governing criterion | Peak sag |
| Sag-limited span | 15.112 ft |
| Stress-limited span | 37.926 ft |
| Mid-span sag | 0.074 in |
| Peak sag | 0.074 in |
| Peak longitudinal bending stress | 1.635 ksi |
| Bending allowance used | 13.6 % |
| Outside diameter | 4.5 in |
| Inside diameter | 4.026 in |
| Nominal wall thickness | 0.237 in |
| Second moment I | 7.233 in⁴ |
| Section modulus Z | 3.214 in³ |
| Total distributed mass | 17.879 lb/ft |
| Pipe mass per length | 10.802 lb/ft |
| Fluid mass per length | 5.508 lb/ft |
| Insulation mass per length | 1.569 lb/ft |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Sum the distributed mass17.879 lb/ft
- Calculate peak sag at trial spacing0.074 in
- Use the shorter limit15.112 ft
The drainage sag limit can govern well before steel bending reaches its allowance. Use the combined distributed mass.
Model and limits
The steel section uses nominal OD and wall dimensions. The distributed load includes the steel wall, full contents when selected, and the insulated annulus. The choice is between a simply supported span and two equal continuous spans carrying the same uniform load.
Default peak sag allowance is 0.10 in (2.54 mm). The sag peak for two equal spans is at about 42% of span from the outer support. The largest absolute bending moment is at the interior support. Include pressure, localized component loads, thermal loads, corrosion, support stiffness and combined sustained stress in the final B31.1 or B31.3 review.
View equations and references