ASME B31.1 / B31.3 beam screen

Four-inch filled and insulated line

A steel process-water line carries insulation and fluid between two simple supports.

Inputs

Steel pipe section
Distributed loading
Spacing criteria
Maximum span
15.11ft
Mid-span sag
0.074in
Line mass
17.88lb/ft
Stress used
13.6%
Span within screening limit

Peak sag governs the calculated span. Full longitudinal stress and support loads need a separate check.

Support spacing and sag

Support spacing and sagVertical movement is exaggerated. The marker shows peak sag, which shifts away from mid-span for two equal continuous spans.SPAN L14 ftMID-SPAN δ0.074 inUNLOADEDLOADEDPEAK SAG0.074 inSAG LIMIT0.1 inSPAN LIMIT15.11 ft
Vertical movement is exaggerated. The marker shows peak sag, which shifts away from mid-span for two equal continuous spans.

All calculated values
Screened support span15.112 ft
Governing criterionPeak sag
Sag-limited span15.112 ft
Stress-limited span37.926 ft
Mid-span sag0.074 in
Peak sag0.074 in
Peak longitudinal bending stress1.635 ksi
Bending allowance used13.6 %
Outside diameter4.5 in
Inside diameter4.026 in
Nominal wall thickness0.237 in
Second moment I7.233 in⁴
Section modulus Z3.214 in³
Total distributed mass17.879 lb/ft
Pipe mass per length10.802 lb/ft
Fluid mass per length5.508 lb/ft
Insulation mass per length1.569 lb/ft

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Sum the distributed mass17.879 lb/ft
  2. Calculate peak sag at trial spacing0.074 in
  3. Use the shorter limit15.112 ft

The drainage sag limit can govern well before steel bending reaches its allowance. Use the combined distributed mass.

Model and limits

The steel section uses nominal OD and wall dimensions. The distributed load includes the steel wall, full contents when selected, and the insulated annulus. The choice is between a simply supported span and two equal continuous spans carrying the same uniform load.

Default peak sag allowance is 0.10 in (2.54 mm). The sag peak for two equal spans is at about 42% of span from the outer support. The largest absolute bending moment is at the interior support. Include pressure, localized component loads, thermal loads, corrosion, support stiffness and combined sustained stress in the final B31.1 or B31.3 review.