ACI 318-19 §9.6 / §9.7 / §22.5

Axial tension reduces concrete shear

Tension along a beam reduces the concrete component despite a regular stirrup layout.

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 0kip
Stirrup Vs 35.48kip
φVn 26.61kip
Spacing max 10.75in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 12 ins 8 inVs 35.48 kip

Screening

Limit exceeded
Shear utilization150.3%
Table 22.5.5.1(a)50.3% over the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Outside limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Within limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Within limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Within limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc0 kip
Provided stirrup Vs35.48 kip
Design shear φVn26.61 kip
Maximum stirrup spacing10.75 in
Minimum stirrup area Av,min0.08 in²
Minimum steel demand trigger12.24 kip
Required stirrup Vs53.33 kip
Diagonal compression Vs cap130.54 kip
Size effect λs (applied)1
Longitudinal ratio ρw0.919 %
Axial stress contribution-127.31 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Axial Nu (+ compression)
-220 kip
Factored shear Vu
40 kip

Calculated result

Concrete shear Vc
0 kip
Provided stirrup Vs
35.48 kip
Design shear φVn
26.61 kip
Maximum stirrup spacing
10.75 in

The negative Nu term reduces Vc, with a zero floor. The vertical stirrup contribution is unchanged.

Preset screening · Table 22.5.5.1(a) · Limit exceeded

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).