ACI 318-19 §9.6 / §9.7 / §22.5

High shear changes the spacing band

A heavy two-leg cage enters the tighter spacing band in a deep member.

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 39.47kip
Stirrup Vs 176.06kip
φVn 147.99kip
Spacing max 6.5in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 12 ins 7 inVs 176.06 kip

Screening

Limit exceeded
Shear utilization81.1%
Table 22.5.5.1(a)18.9% below the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Within limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Within limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Within limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Outside limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc39.47 kip
Provided stirrup Vs176.06 kip
Design shear φVn147.99 kip
Maximum stirrup spacing6.5 in
Minimum stirrup area Av,min0.07 in²
Minimum steel demand trigger14.8 kip
Required stirrup Vs120.53 kip
Diagonal compression Vs cap157.86 kip
Size effect λs (applied)1
Longitudinal ratio ρw0.76 %
Axial stress contribution0 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Overall depth h
29 in
Effective depth d
26 in
Factored shear Vu
120 kip
Leg area Av
0.79 in²
Stirrup spacing s
7 in

Calculated result

Concrete shear Vc
39.47 kip
Provided stirrup Vs
176.06 kip
Design shear φVn
147.99 kip
Maximum stirrup spacing
6.5 in

Once the tighter band applies, compare spacing with d/4 and 12 in. Adequate shear strength does not excuse excess spacing.

Preset screening · Table 22.5.5.1(a) · Limit exceeded

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).