Concrete Vc
21.78 kip
Stirrup Vs
0 kip
φVn
16.34 kip
Spacing max
10.75 in
Anatomy Diagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in Av = 0 Vs 0 kip
Screening Limit exceeded
Shear utilization 88.7%
Table 22.5.5.1(c) 11.3% below the threshold
Shear strength Vu ≤ φ(Vc + Vs, credited)
Within limit Diagonal compression Required Vs ≤ 8√f′c bw d
Within limit Minimum stirrup area Av ≥ Av,min when Vu > φλ√f′c bw d
Outside limit Stirrup spacing Longitudinal spacing ≤ smax
Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.
Calculation readout Quantity Value
Concrete shear Vc 21.78 kip Provided stirrup Vs 0 kip Design shear φVn 16.34 kip Maximum stirrup spacing 10.75 in Minimum stirrup area Av,min 0.08 in² Minimum steel demand trigger 12.24 kip Required stirrup Vs 0 kip Diagonal compression Vs cap 130.54 kip Size effect λs (applied) 0.797 Longitudinal ratio ρw 0.919 % Axial stress contribution 0 psi Transverse yield used 60 ksi
Share link
Reset defaults
JSON
CSV
SVG
PNG ×2
Print A4
Starting inputs
Factored shear Vu 14.5 kip
Leg area Av 0 in²
Calculated result
Concrete shear Vc 21.78 kip
Provided stirrup Vs 0 kip
Design shear φVn 16.34 kip
Maximum stirrup spacing 10.75 in Compare Vu with φλ√f′c bw d as well as with φVc. The minimum-reinforcement trigger and strength answer different design questions.
Preset screening · Table 22.5.5.1(c) · Limit exceeded
Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).
RebarStructLab • ACI 318-19 • US
§9.6 / §9.7 / §22.5
Insufficient stirrups at moderate demand
Vertical stirrups · rectangular web · Limit exceeded
Inputs
Web width bw 12 in
Overall depth h 24 in
Effective depth d 21.5 in
Longitudinal steel As 2.37 in²
Axial Nu (+ compression) 0 kip
Factored shear Vu 14.5 kip
Concrete strength f′c 4,000 psi
Lightweight factor λ 1
Leg area Av 0 in²
Stirrup spacing s 8 in
Transverse yield fyt 60 ksi
Calculated values
Concrete shear Vc 21.78 kip
Provided stirrup Vs 0 kip
Design shear φVn 16.34 kip
Maximum stirrup spacing 10.75 in
Minimum stirrup area Av,min 0.08 in²
Minimum steel demand trigger 12.24 kip
Required stirrup Vs 0 kip
Diagonal compression Vs cap 130.54 kip
Size effect λs (applied) 0.797
Longitudinal ratio ρw 0.919 %
Axial stress contribution 0 psi
Transverse yield used 60 ksi
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in Av = 0 Vs 0 kip
Screening
Table 22.5.5.1(c) · Shear utilization 88.7%
Shear strength · Within limitDiagonal compression · Within limitMinimum stirrup area · Outside limitStirrup spacing · Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.