ACI 318-19 §9.6 / §9.7 / §22.5

Insufficient stirrups at moderate demand

A beam with no transverse steel crosses the minimum-reinforcement demand trigger.

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 21.78kip
Stirrup Vs 0kip
φVn 16.34kip
Spacing max 10.75in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 12 inAv = 0Vs 0 kip

Screening

Limit exceeded
Shear utilization88.7%
Table 22.5.5.1(c)11.3% below the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Within limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Within limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Outside limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Within limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc21.78 kip
Provided stirrup Vs0 kip
Design shear φVn16.34 kip
Maximum stirrup spacing10.75 in
Minimum stirrup area Av,min0.08 in²
Minimum steel demand trigger12.24 kip
Required stirrup Vs0 kip
Diagonal compression Vs cap130.54 kip
Size effect λs (applied)0.797
Longitudinal ratio ρw0.919 %
Axial stress contribution0 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Factored shear Vu
14.5 kip
Leg area Av
0 in²

Calculated result

Concrete shear Vc
21.78 kip
Provided stirrup Vs
0 kip
Design shear φVn
16.34 kip
Maximum stirrup spacing
10.75 in

Compare Vu with φλ√f′c bw d as well as with φVc. The minimum-reinforcement trigger and strength answer different design questions.

Preset screening · Table 22.5.5.1(c) · Limit exceeded

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).