ACI 318-19 §9.6 / §9.7 / §22.5

Dense stirrups at the crushing ceiling

An unrealistically tight stirrup layout shows that spacing cannot remove the diagonal compression limit.

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 32.63kip
Stirrup Vs 1,135.2kip
φVn 122.38kip
Spacing max 5.38in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 12 ins 0.5 inVs 1,135.2 kip

Screening

Limit exceeded
Shear utilization114.4%
Table 22.5.5.1(a)14.4% over the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Outside limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Outside limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Within limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Within limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc32.63 kip
Provided stirrup Vs1,135.2 kip
Design shear φVn122.38 kip
Maximum stirrup spacing5.38 in
Minimum stirrup area Av,min0.005 in²
Minimum steel demand trigger12.24 kip
Required stirrup Vs154.03 kip
Diagonal compression Vs cap130.54 kip
Size effect λs (applied)1
Longitudinal ratio ρw0.919 %
Axial stress contribution0 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Factored shear Vu
140 kip
Leg area Av
0.44 in²
Stirrup spacing s
0.5 in

Calculated result

Concrete shear Vc
32.63 kip
Provided stirrup Vs
1,135.2 kip
Design shear φVn
122.38 kip
Maximum stirrup spacing
5.38 in

The required Vs exceeds the credit allowed by the web despite the dense cage. Check the section limit before considering more stirrups.

Preset screening · Table 22.5.5.1(a) · Limit exceeded

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).